We have exhibited our devices on the prestigious MEDTEC UK exhibition in Birmingham
ONKOCET Ltd. has exhibited the devices from its portfolio on the MEDTEC UK exhibition in Birmingham, April 2011 through our partner Medical & Partners.
12.4.2011 12:27
Certification of SVIT infrared camera completed The ONKOCET company has successfully reached the certification of yet another medical device,
Infrared Camera SVIT. The Certificate can be found
here. The videos from the device operation can be found
here.
4.3.2011 11:38
Certification of Concor Soft Contact Lenses successfully finished. We are pleased to inform our business partners, that our company has succesfully finished the certification process of Concor Soft Contact Lenses.
You can find the certificate
here.
More information on Concor Soft Contact Lenses go to section Medical preparations/Concor soft contact lenses, or follow
this link.
16.6.2010 11:51
Certification of MAS-1K Spirometer successfully finished. Our company has finished the certification process for another medical device, computerized spirometer MAS-1K with oximeter. You can find the device certificate
here.
2.6.2010 10:58
Certification of PLASON device finished, CE issued. Dear partners,
In October 2009 we have received
CE certificate for another device from our portfolio, NO therapeutical device PLASON. You can find more information about this revolutionary device, used for healing of unhealing wounds, diabetic foot, or for cosmetical purposes, at our webpage, section "Medical devices" -> PLASON-NO Therapy.
Best regards
Team of ONKOCET Ltd. company
23.1.2009 15:30
Flow parameters
Temperature and the content of nitrogen oxides - fundamental characteristics of the air-plasma flows
Temperature and content of the nitrogen oxide in it are the basic physical chemistry flow parameters (NO). The temperature of expiration for destructor and coagulator composes ~4000 °C, and for the simulator-coagulator - ~1000 °C (Pic. 1).
The temperature of flow is rapidly reduced with the removal from the outlet of manipulator and at a distance 100 mm does not exceed 100°C. The content of nitrogen oxides on the axis of gas flow represented in Pic. 2.
It should be noted that the molecule of the nitrogen oxide possesses active oxidation potential and in the air medium enters into the reaction with molecular oxygen with the formation of chemically resistant compound - the nitrogen dioxide (NO2), which as a result of this will always be present in the NO-containing gas flow.
The application of the standardized generator part of all manipulators makes it possible to obtain flows with the identical axial content of the nitrogen oxide, what also shown in Pic. 2. Range of the obtained concentrations NO is very wide - from 2500 ppm to zero. This makes it possible to select those parameters, which it considers most acceptable for doctor.
The analysis of dependence of temperature and content of the nitrogen oxide on the axis of gas flow shows that the apparatus allows the enormous field of possibilities on the combining of the thermo-physical and biochemical factors of action on the biological tissues and objects for the user.