Manipulator | Designation |
Coagulator | It is intended for:
1. action by high-temperature air-plasma flow with the temperature of ~4000°C on the biological tissues for the purpose of obtaining effect of hemo- aero- lympho- cholestasis. The cessations of diffuse hemorrhages and coagulation of the vessels with a diameter are not more than 1,0 mm;
2. action on the biological tissues by air-plasma flow with the temperature to ~1000°C for obtaining the effect of sterilization;
3. remote action on the biological tissues, opened pathologic regions and objects by the air flow, which contains the molecules of the nitrogen oxide. NO- therapy. |
Destructor | It is intended for:
1. The thermal degradation (evaporation) of abiosis cloths and pathologic formations;
2. Dissection and intersection of biological tissues and hollow organs with the simultaneous coagulation it is boundary section;
3. Remote conducting of the sessions of the NO-therapy of open domains and objects. |
Stimulator- Coagulator | It is intended for:
1. local action on the biological tissues by air-plasma flow with the temperature not more than 1000°C with the purpose of the thermal destruction of pathogenic flora (sterilization), of cessation of diffuse hemorrhages and final evaporation of physiological and pathologic liquids in the operating field;
2. action on the biological structures and the open pathologic regions by NO-containing gas flow. Stimulator-coagulator - basic tool for the NO-therapy of open domains. |
Manipulator for small access* | It is intended for:
1. manipulation in the almost inaccessible cavities and the pockets for the purpose of obtaining surgical effects - coagulation and the sterilization;
2. intra-operating of almost inaccessible cavities and pockets by the NO-containing gas flow. Manipulator for the small access can work in the composition of endovideosurgical complex. |
Manipulator for laparoscopy | It is intended for:
1. work in the content of the regular laparoscopy equipment as the coagulator for the cessation of hemorrhages, evaporation of pathologic formations and sterilization of wound surfaces;
2. intra-operating working by the NO-containing gas flow of cavities with laparoscopy surgery. Manipulator for laparoscopy is introduced into the cavity through the standard trocar with a diameter of 10 mm and works in the content of the regular laparoscopy equipment. |
Tip for the supply NO-containing gas flow** | It is intended for:
1. delivery of the completely cooled NO-containing gas flow directly to the region of the pathology independent of its localization;
2. connection to the drainages with conducting of the NO-therapy of the drained cavities;
3. connection to the endoscopic instruments for the delivery of the NO-containing gas flow to the region of pathology through the unequipped channels of endoscope. |