Medical devices
search
news
We have exhibited our devices on the prestigious MEDTEC UK exhibition in Birmingham
ONKOCET Ltd. has exhibited the devices from its portfolio on the MEDTEC UK exhibition in Birmingham, April 2011 through our partner Medical & Partners.
12.4.2011 12:27
Certification of SVIT infrared camera completed The ONKOCET company has successfully reached the certification of yet another medical device,
Infrared Camera SVIT. The Certificate can be found
here. The videos from the device operation can be found
here.
4.3.2011 11:38
Certification of Concor Soft Contact Lenses successfully finished. We are pleased to inform our business partners, that our company has succesfully finished the certification process of Concor Soft Contact Lenses.
You can find the certificate
here.
More information on Concor Soft Contact Lenses go to section Medical preparations/Concor soft contact lenses, or follow
this link.
16.6.2010 11:51
Certification of MAS-1K Spirometer successfully finished. Our company has finished the certification process for another medical device, computerized spirometer MAS-1K with oximeter. You can find the device certificate
here.
2.6.2010 10:58
Certification of PLASON device finished, CE issued. Dear partners,
In October 2009 we have received
CE certificate for another device from our portfolio, NO therapeutical device PLASON. You can find more information about this revolutionary device, used for healing of unhealing wounds, diabetic foot, or for cosmetical purposes, at our webpage, section "Medical devices" -> PLASON-NO Therapy.
Best regards
Team of ONKOCET Ltd. company
23.1.2009 15:30
Destructor
Destruction (dissection)
Basic difference in the manipulator -destructor from the coagulator - diameter of outlet (coagulator 1,2 mm, destructor 0,7 mm). This constructive solution makes it possible to aggravate and to concentrate energy of air- plasma flow (APF) and, furthermore, to increase the speed of its expiration.
In working of living biological tissues concentrated and aggravated APF of destructor the carbon layer of necrosis is heated to the temperature of ~800°C and it begins to be decomposed into the small particles - to sublimate, and high-speed flow takes away ("exhausting") decay products [CaLN] from the zone of action.
With this dynamics the carbon layer of necrosis ceases to be natural heat shield as in the case of coagulator, and entire structure of the region of thermal changes is moved into the depths of the cloth. As a result is formed the zone of the destructured cloths, surrounded by the coagulation layer, which ensures reliable hemostasis.
Effective distance from the outlet of manipulator must be smallest possible. This makes it possible to obtain qualitative section with putting of smallest possible damages to the adjacent cloths and to organs.