ONKOCET
high technology in medical equipment


Medical devices


search


news

NCDS clinic now open  

Check out the new website of NCDS Clinic in Bratislava.


18.5.2015 12:03
Pictures from NO therapy of diabetic foot by PLASON device

The PDF with the short report with pictures from the therapy of a diabetic foot can be viewed or downloaded here

The pictures from the treatment of unhealing wounds an be found here:
http://www.onkocet.eu/en/produkty-detail/220/1/

The pictures from the treatment of unhealing wounds an be found here:
http://www.onkocet.eu/en/produkty-detail/293/1/

12.5.2011 12:23
We have exhibited our devices on the prestigious MEDTEC UK exhibition in Birmingham

 
ONKOCET Ltd. has exhibited the devices from its portfolio on the MEDTEC UK exhibition in Birmingham, April 2011 through our partner Medical & Partners.

MEDTEC UK exhibition medical device

12.4.2011 12:27
Certification of SVIT infrared camera completed

The ONKOCET company has successfully reached the certification of yet another medical device, Infrared Camera SVIT. The Certificate can be found here. The videos from the device operation can be found here.
4.3.2011 11:38
Certification of Concor Soft Contact Lenses successfully finished.  

We are pleased to inform our business partners, that our company has succesfully finished the certification process of Concor Soft Contact Lenses.

You can find the certificate here.

More information on Concor Soft Contact Lenses go to section Medical preparations/Concor soft contact lenses, or follow this link.
16.6.2010 11:51
Certification of MAS-1K Spirometer successfully finished.

Our company has finished the certification process for another medical device, computerized spirometer MAS-1K with oximeter. You can find the device certificate here.
2.6.2010 10:58
New version of AMP device available   

Since May 2010 there is a new version of AMP device available.



Follow this link if you want to see the pictures and specifications of the device.



11.5.2010 15:17
Treatment of burns with PLASON We added photographs of treatment of burns with PLASON device: 
http://www.onkocet.eu/en/produkty-detail/293/1/
17.3.2010 12:08
Certification of PLASON device finished, CE issued.

Dear partners,

In October 2009 we have received CE certificate for another device from our portfolio, NO therapeutical device PLASON. You can find more information about this revolutionary device, used for healing of unhealing wounds, diabetic foot, or for cosmetical purposes, at our webpage, section "Medical devices" -> PLASON-NO Therapy.



Best regards

Team of ONKOCET Ltd. company

23.1.2009 15:30

NO-therapy by the stimulator-coagulator


Technology of conducting the sessions of NO-therapy by the stimulator-coagulator 

Stimulator-coagulator as device with the part cooler connected to the generator generates the gas flow, which contains the nitrogen oxide, with temperature potential smaller than coagulator or destructor. With conducting of the sessions of NO-therapy this circumstance makes it possible to draw the manipulator nearer to the biological subject and as a result, create higher concentration in the near-surface layers. The flow chart of conducting the sessions of NO-therapy by stimulator-coagulator is shown in the Fig. a. 

According to the dependence of the content of the nitrogen oxide on the axis of flow minimum distance from the outlet to the surface, where the temperature will not exceed 40±10°C, is about 80 mm (temperature and the content of oxides of nitrogen - fundamental characteristics of the air-plasma flows).

Directed desirably the right angle to the workable object flow will smoothly spread in parallel to surface, creating axisymmetrical region with the increased content of the nitrogen oxide.

The center of luminescent spot will be indicated to user, where the flow is directed to the given moment. The effective scope diameter of the workable surface is tentatively defined as fourth of distance from the outlet of manipulator to the surface. For averting the possibility of putting the thermal damages the construction provides for installation to the stimulator-coagulator of the detachable thermal spacer, whose application makes it possible to fix the physical chemistry parameters of flow (Fig. b).

Thermal spacer is executed in the form of hollow cylinder with the wide lateral windows. Its length is selected in such a way that the temperature of the NO-containing gas flow (NO-CGF) on the end of spacer would compose 40±10°C, in this case the concentration of the nitrogen oxide will have a value of ~750 ppm. The installation of thermal spacer does not introduce changes in geometric parameters NO-CGF. The effective scope diameter on the previous composes fourth from the distance and in the case of a maximally possible approximation of stimulator- coagulator with the thermal spacer to the workable object established on it composes ~20 mm.


2009 © Copyright Onkocet, s.r.o.
Všetky práva vyhradené. Realizácia: bk studio
home | devices | preparations | supplements | equipment |references | contact